An interface board needs tests on both sides of its nominal reference to determine receiver margin. TI's LMK61E2 supports I²C coarse and fine tuning for system validation. Its factory nonvolatile configuration defaults to 156.25 MHz LVPECL. Specify tuning range, steps, and recovery during purchasing review. Verify that the receiver supports LVPECL before connecting it even if the default frequency matches.
Convert ppm into a quantity the instrument can display
At 156.25 MHz, each side of ±100 ppm corresponds to 15.625 kHz. If that is the intended test range, record the baseline, both targets, and the actual frequencies reached. Have engineering decide whether tuning must be continuous or may require relock. Programmability and uninterrupted traffic during a transition are separate requirements. In the RFQ, specify output standard, supply, target step size, and whether receiver reset is allowed during changes.
Keep a verified path back to the production configuration
Save temporary test settings separately from power-up defaults. At each step, verify actual frequency and output before reading receiver error counts or link status. After testing, verify normal frequency and power-cycle to check the default output. Do not leave deliberate offset active for subsequent functional tests. If only a bench solution is required, distinguish evaluation board, standalone device, and control tools in the quote.
Report actual input offset paired with observed link behavior. The result demonstrates margin under the tested conditions. Deliberate clock offsets do not measure long-term stability of a fixed production source. TI LMK61E2 margin testing and default configuration