A frequency synthesizer uses the same 100 MHz SMD oscillator, yet one digital setting changes its discrete spectral lines. TI measured the relationship between LMX2820 MASH_SEED and fractional spurs. At a fractional division point, verify the modulator's initial state as a separate variable. Keep reference and supply unchanged first so configuration effects are not attributed to the oscillator lot.
Record reference frequency, phase detector frequency, integer divider, fractional numerator and denominator, and MASH order. Two projects with the same output frequency can use different internal plans. Apply each seed using the documented sequence, save the full register settings and wait for settling before measuring at the same resolution bandwidth, attenuation and span. Keep carrier power visible for relative spur readings in dBc.
Mark the receiver's critical offset band and compare the location and level of the strongest spur there for each seed. Keep a wider span as well, since suppressing one spur can raise another. TI's measurements apply to its specific fractional settings, order and test conditions. They do not establish one universally preferable seed or a suppression guarantee for the customer's board.
To assess a reference upgrade, fix the chosen seed and divider settings, change only the reference to a compatible source, and compare the same offsets. Record worst spur, bandwidth and register revision by channel, separately tracking changes due to the seed and changes due to the source. This shows which metric a purchasing upgrade can affect.TI application report SNAA413: measured MASH_SEED and spur behavior