An older board has a 4 MHz oscillator, and engineering wants to clock a switched-capacitor filter with it. Start with the complete suffix and actual circuit. The LTC1068 family provides second-order building blocks that can be combined, with different clock-to-center-frequency ratios for different variants. A ratio copied from the family name can put the response in the wrong band.
Start with the ratio for the exact model
The LTC1068-200 has a nominal 200:1 clock-to-center-frequency ratio. If the clock input and application conditions are valid for that configuration, 4 MHz divided by 200 gives a reference center frequency of 20 kHz. Check the actual pole locations and response using the selected operating mode, external network, and manufacturer’s equations. With cascaded sections, the complete filter’s −3 dB cutoff need not equal one section’s center frequency.
Apply a sine wave of known amplitude. Measure the output-to-input ratio at several frequencies in the expected passband, transition region, and stopband. Change the clock slightly and check whether the response moves proportionally. If the center shifts but peak gain or bandwidth differs from expectations, inspect resistor ratios, Q, and cascade order. Keep a response sweep instead of a single gain screenshot.
Check the clock waveform against the filter supply levels, and verify permitted clock amplitude, frequency, and layout in the applicable manual. If the output spectrum contains clock-related components, repeat the measurement with the input shorted or quiet. Include the filter part number and measured passband conditions in the purchase specification so a later substitution is evaluated on more than the LTC1068 family name.ADI LTC1068 series manual for clock-tunable filters