A text overlay can stay visible after the camera is unplugged, which can be mistaken for valid input. The MAX7456 has an internal timing generator and can extract sync from external composite video. Automatic mode selects a source according to input conditions. A running 27 MHz reference explains how internal timing can continue. It does not establish that a valid video frame is arriving.
Keep the overlay content fixed and capture input waveform, output sync and chip status with video connected and disconnected. Read sync selection and video standard from VM0 and check whether the software forces internal or external sync. Use obvious motion in the camera image, such as moving a page with printed numbers, to distinguish a retained text layer from a combined image that still contains live camera video.
If characters stay visible in automatic mode after the camera image disappears, check loss-of-sync status and behavior when the source is reconnected. Reconnect using the same standard and termination, and capture consecutive frames to see when the output follows the input again. If forcing external sync reveals a fault only with weak input, a mismatched standard or a changed cable, inspect the input path first. If forced internal sync also fails, check supply, configuration and reference clock.
Report two separate results: characters can appear with no input, and characters can be overlaid reliably on camera video with an input present. One photo of a static screen with text is weak evidence for the second result. Retain status before and after disconnect, video standard and sync selection so loss and recovery can be retested after substituting a crystal with the same frequency.Analog Devices MAX7456 datasheet: video synchronization selection and status register