A batch of Epson MC-146 crystals arrives for an RTC board. The incoming lab needs to set the drive on its crystal test set. Epson's brief has three values in microwatts. The drive line lists a 1.0 µW maximum, its note gives a 0.5 µW operating maximum, and the frequency tolerance line specifies 0.1 µW. The purchasing question is which conditions to put in the inspection record. Engineering has a different question and needs to check the power dissipated by the crystal on the assembled board.
Put each figure in the record it belongs to
| Where to look in Epson's brief | What the figure describes | Where to use it |
|---|---|---|
| Frequency tolerance, +25 °C and 0.1 µW | The temperature and drive used for the stated initial tolerance | Incoming frequency test, with the ordered load capacitance and tolerance grade |
| Drive note, 0.5 µW maximum in operation | The maximum drive in operation | Board qualification across the supply, temperature and drive settings relevant to the product |
| Drive line, 1.0 µW maximum | The ceiling stated in the drive specification line | Preserve the field in the review and resolve any higher transient drive with the manufacturers |
The brief does not give a permitted time above the operating limit or describe an allowable startup waveform at 1.0 µW. On an RTC that changes drive automatically, document the settings from reset to steady state and the time spent in each one. Use the operating limit when assessing the running crystal. If a startup profile would exceed that figure, have the relevant manufacturers confirm the measurement definition and permitted conditions before qualifying the profile.
The MC-146 is a passive 32.768 kHz crystal unit in a 7.0 × 1.5 × 1.4 mm package. The brief lists nominal load capacitances of 7, 9 and 12.5 pF and standard initial tolerance options of ±20, ±50 and ±100 ppm. Ask for the exact ordering code and packaging along with the load and tolerance options. For example, Epson's PCF85263 guide lists the 12.5 pF MC-146 in a table for a specific evaluation board and register setting. It points to separate packaging details. A different PCB still needs its own circuit check. Epson MC-146 brief, page 1 · Epson evaluation guidance for PCF85263
Turn the ordered tolerance into a fixture limit
Suppose the purchase order specifies 32.768 kHz, 12.5 pF and ±20 ppm. At the specified reference condition, 20 ppm of 32,768 Hz is 0.65536 Hz. The resulting limits are 32,767.34464 Hz and 32,768.65536 Hz. Enter +25 °C, 0.1 µW and the 12.5 pF load condition on the same test sheet. Record the reference used by the instrument. On the board, the effective load includes the input and PCB capacitance as well as the fitted capacitors. The fixture's load value by itself does not give the capacitor values to fit on the board.
Now assume the fixture reads 32,768.60 Hz, about +18.31 ppm. The displayed value is 0.05536 Hz below the theoretical upper limit. An expanded measurement uncertainty of 0.08 Hz would put part of the measurement interval above that limit. Apply the decision rule agreed with the supplier. If a retest is called for, use the agreed fixture and a checked reference, and record the original measurement and its uncertainty. Extra digits in the display provide no additional evidence about the part.
Keep this result with the incoming inspection. It gives the crystal's initial frequency under defined conditions. A battery-backed product that operates across seasons needs a separate timing budget, including temperature, the load on the board and aging over the intended period. When the order moves to ±50 ppm, update the incoming window to match that option.
Estimate drive from the actual current and the matching resistance
For a board-level drive estimate, square the RMS crystal terminal current and multiply it by the load resonance resistance RL. Amperes squared times ohms gives watts. Epson also lists a 65 kΩ maximum motional resistance R1 and a typical 0.8 pF shunt capacitance. These describe crystal model parameters. A typical value and a maximum from the brief, taken together, do not establish the load resonance resistance of the particular unit being tested. A defined load fixture and a current measurement that matches that method make the result reproducible.
Take a hypothetical unit with a measured 74 kΩ load resonance resistance. An operating current of 3.00 µA RMS gives 0.666 µW, which is above the 0.5 µW operating limit. Suppose a different approved setting reduces the current to 2.50 µA RMS. The estimate is now 0.4625 µW. With separate upper error bounds of 5% on current and 4% on resistance, using both upper bounds gives about 0.530 µW. That case needs more measurement or design margin. For a nearly sinusoidal current displayed as 7.07 µA peak to peak, divide by 2√2 to obtain approximately 2.50 µA RMS before squaring. Squaring the peak-to-peak number directly would give about eight times the power. NDK manufacturer guidance on fixture resistance and crystal current
Before relying on the measurement, compare the startup and frequency with and without the measurement leads and adapter. A change after the connection is made means the test arrangement needs attention. Check the adjusted drive, clock-source status and startup time at the supply and temperature limits required by the product. An RTC that starts successfully at room temperature can still miss the required first-start deadline on a cold or weak supply.
Send the result to the team that can act on it
If the part is out of tolerance on the agreed fixture after retest, send the supplier the full code, lot, settings and measurement evidence. When the crystal passes incoming inspection but the board still runs slow, engineering needs the fitted capacitors, oscillator register settings, firmware clock-source record and measurement connection. When steady drive is high, review the available drive settings and verify that lowering drive also leaves enough startup margin. If purchasing is considering a different load option, link the replacement code to the board revision and test evidence before putting it on the approved list.