An infrared service terminal needs a faster serial rate. Doubling the 7.3728 MHz crystal provides higher bit rates with some MCP2120 settings. Microchip’s application note includes a baud-rate table and a footnote: when oscillator frequency exceeds 7.5 MHz, TXIR pulses are shorter than the cited 1.6 µs condition. Both clock choices can produce a desired serial rate while producing different infrared pulse widths.
Specify the electrical interface and optical link separately
List the peer’s serial rate, MCP2120 baud-select pins or configuration, and pulse limits for the transceiver and peer. Use the same selection row when reading the manufacturer table. If a row divides oscillator frequency by 128, changing frequency changes its bit rate. A result taken from another row does not establish an equal pulse width. Check any mandatory interface requirement against the full specification.
Qualify samples with the actual optical transceiver
Capture UART data and the pulses driving the infrared transmitter separately. State whether the probe is at the logic interface or optical receiver. If reception is intermittent at close range, investigate short pulses, drive capability, and link distance separately. Test the actual optical module, both ends, sustained data, and target distance. A wired UART loopback does not test the optical link.
Order the validated oscillator frequency and board configuration. For a different rate, update the fitted select pins or firmware, and add optical pulse width to the change acceptance record. Baud rate alone does not qualify the change. Microchip AN756 oscillator frequency and infrared pulse guidance