The reader specification says 13.56 MHz, but the prototype contains a crystal marked at a different frequency. Identify the actual front-end IC and list the antenna carrier, internal timer input, and reference at the crystal pins separately. In the MFRC522 example, the manufacturer's clock circuit uses a 27.12 MHz quartz crystal, from which it derives the 13.56 MHz internal timer clock. Use the system band in equipment documentation and the IC reference requirements for crystal ordering.
Trace the pads to the point where each frequency appears
Trace OSCIN and OSCOUT on the schematic to find the crystal designator, then check whether the BOM abbreviates 27.12 MHz as 27 MHz. The difference is 0.12 MHz, approximately 0.44% relative to 27.12 MHz. Division preserves that relative difference. Even when the package, load option, and lead time fit, send the item back for nominal-frequency confirmation. Ordinary trimming cannot make the two values interchangeable.
If the prototype already emits RF, use near-field coupling without appreciably loading the antenna to locate the carrier, then compare against the configuration record. Confirm that firmware has enabled the transmit driver. If there is no discernible signal near the coil, check power, operating mode, and the antenna network. With transmission disabled, a reading near the antenna alone cannot establish crystal startup.
Keep separate documents for separate reviews. The RF verification record gives the measured carrier and test position. The purchasing specification gives the quartz crystal's complete order code, nominal frequency, and electrical conditions. A change to another reader IC requires rechecking how that front end generates its carrier. An unchanged RF band on the enclosure does not establish that the old crystal can be reused.NXP MFRC522 oscillator, modulator, and timer documentation