Engineering wants to lower emissions on an automotive Ethernet module. The original clock drove one PHY, and the new board adds a branch to the main controller. Microchip uses DSA6103JA3-050.0000VAO as a low-drive example for 10BASE-T1S RMII and describes driving multiple endpoints. That makes the exact part a trial candidate. Whether this 50 MHz active oscillator can cover two particular chips and traces requires actual loading and receiver measurements. The quoted low-drive configuration alone does not qualify every two-branch board.
Bring the electrical test conditions into the review
The DSA61xx data sheet has low, standard and high output-drive variants. For the DSA61x3 low-drive option, output transition times use 5 pF and the 20% to 80% interval. At 2.5 or 3.3 V, the typical value is 2.0 ns and the maximum is 3.3 ns. At 1.8 V, the typical and maximum values are 3.2 and 5.4 ns. The standard- and high-drive options have separate transition-time loads of 10 and 15 pF, respectively. Use each row at its own test condition. Put the exact ordered number, supply, receiver arrangement and edge requirements in the trial request.
Frequency stability is a separate acceptance item. Code 3 in the series ordering table gives ±20 ppm, or ±1,000 Hz at 50 MHz. For RMII, the LAN8670 and LAN8671 need a 50 MHz single-ended source within ±100 ppm or better. That corresponds to ±5,000 Hz. The oscillator stability footnote includes initial tolerance, temperature and supply variation, while first-year aging is listed separately. Frequency latitude does not resolve a failed logic level or duty-cycle requirement at a receiver. A single counter reading covers only one part of clock delivery.
Estimate the load and check both receivers
Suppose the PHY input is 3 pF, the main controller input another 3 pF, and routing and pads add 2 pF. The nominal sum is 8 pF. A 1 pF probe takes the simplified estimate to 9 pF. Both values exceed the load at which the low-drive transition time is specified. The board could still work. The 3.3 ns limit cannot simply be applied to this assembly. If the edge limit is mandatory, include the 9 pF test arrangement and worst supply condition in the trial plan. Keep track of when the probe is attached.
The single lumped value also misses branch effects. Each receiver may see different steps, ringing and threshold-crossing times. Capture the oscillator output and then both receivers. Record ground connections, board revision and probe loading. Measure the original single-branch build first, then fit the other branch and repeat with the relevant power sequences. If one receiver can lose power independently, check whether it drags down the clock net when off. These records show where the problem appears and whether it arose on the bench load or in the real assembly.
At 3.3 V, the low-drive DC thresholds are 0.8 times the supply for the minimum output high and 0.2 times the supply for the maximum output low, or 2.64 V and 0.66 V. The data sheet defines those at 1 mA sourcing and sinking respectively. Use them to start the DC review, then apply the two receivers' own thresholds and noise budgets. Check dynamic edges separately. Save both forms of evidence in the first-article report.
The product introduction also mentions 13 ps RMS period jitter. The low-drive family table gives 13 ps as typical at a test frequency of 27 MHz and a supply of 2.5 or 3.3 V. If a quotation calls 13 ps a guaranteed board-level limit at 50 MHz, request the applicable part-specific test conditions and acceptance limit. An RMS period-jitter figure does not specify the shortest cycle or peak-to-peak jitter. Where short cycles matter, use the designated probe, receiver threshold and sampling conditions and record the intended metric. Repeat with matching settings before comparing captures from single- and dual-receiver boards.
Define the conditions for accepting an alternate
If the low-drive 50 MHz oscillator passes with both live endpoints, approve the original part against the tested board revision, receivers, termination and supply. If it only passes for one branch, approve it for the one-endpoint board or have hardware isolate or buffer the second branch and qualify the change. A standard- or high-drive substitution needs a new exact order number, receiver waveform checks and a repeated emissions evaluation. Faster edges can restore receiver margin while changing emissions. Decide from the new assembly's measured results.
A single 50 MHz waveform on a fixture does not identify the drive option. Have the supplier confirm drive, package, stability, temperature grade and pin 1 function, and retain the full label. If receiving compares edge rates, control the supply, load and threshold definitions and keep that record distinct from the two-branch assembly result. Link the supplier and lab records before releasing the configuration for later orders.