A repair buyer receives a quotation for a network board reference clock. The spreadsheet displays 156.25 MHz, and an evaluation sample measures close to that number. It seems reasonable to use the existing material entry. Microchip's VC-806 data sheet contains an example that can pass both checks. The family frequency table lists 156.250 MHz and 156.253906 MHz. Both can display as 156.25 to two decimal places. Depending on the stability grade, their allowed frequency bands can also overlap. Before adding digits to a counter reading, determine what the measurement can establish.
Keep nominal frequency, display format and stability separate
The VC-806 is a quartz differential oscillator with LVDS and LVPECL options. The ordering instructions use an M in the frequency field, with six decimal digits in the example. In this format, 156.250000 MHz is 156M250000, and 156.253906 MHz is 156M253906. Those are the frequency fields. A production order still needs the complete manufacturer number, including supply, output, temperature, stability, enable location and packaging. The data sheet says some combinations are unavailable, and the product page lists VC-806 as not recommended for new designs. It is an instructive example for repairs or alternate-source review. Confirm the actual ordering configuration for the current purchase.
Store the complete manufacturer number as text and the nominal frequency separately as an integer in hertz. The comparison keys are 156,250,000 and 156,253,906. A display can use two decimal places for compactness while receiving and purchasing compare the underlying values. If the formatted frequency is used as the material key, the records will merge even after the lab upgrades its counter. Ask the supplier to repeat the exact nominal frequency in the quotation rather than recovering it from a rounded spreadsheet cell.
Calculate the overlap before deciding how to test
The nominal frequencies differ by 3,906 Hz, or about 25.0 ppm relative to 156.250000 MHz. Suppose both configurations are assessed at ±25 ppm. At 156,250,000 Hz the half-width is 3,906.25 Hz, producing a band from 156,246,093.75 to 156,253,906.25 Hz. At the other nominal the half-width is about 3,906.35 Hz and the lower edge is about 156,249,999.65 Hz. The two bands overlap by about 3,906.60 Hz. A reading of 156,252,000 Hz is 2,000 Hz from the first nominal and 1,906 Hz from the second. It can comply with either band. A longer gate improves the precision of the sample reading. It cannot by itself identify which nominal value the factory assigned.
Confirm that the stated stability grade and temperature range are applicable to both full part numbers before using the illustrative bands. The ordinary VC-806 stability footnote includes calibration, temperature, supply, aging and reflow. A separate ±20 ppm option excludes aging and reflow. When inspection uses a different grade, update the footnote and applicable conditions as well as the numerical limit. Room-temperature measurements may give a narrower distribution. Using that distribution for additional screening would call for its own evidence, measurement conditions and written agreement.
Use labels to establish identity and frequency tests to investigate discrepancies
For a 156.25 MHz differential oscillator, keep the complete original label, lot and delivery record. With cut tape, establish the connection between the sample strip and the parent label. Top marks have less room than packing labels, and the data sheet illustrates abbreviated frequency markings. Treat them as supporting evidence. If a top mark looks plausible but the shipping label shows only two decimal places, request documentation that ties the lot to the complete frequency field. Hold unidentified tape while the evidence is gathered and record any measurements as diagnostic checks.
Measure using termination appropriate to the confirmed output. Record the reference, input sensitivity, gate time, measurement point and board identity. A receiver lock test establishes how the sample works in the tested setup. Within the overlap, distinguishing the two configured nominal frequencies requires traceable manufacturer configuration evidence. A reading outside the specified band is grounds to investigate after checking reference and loading. When the documents disagree but the prototype functions, retain the sample's separate identity so a single successful start does not carry an unverified clock into production.
Use known samples to validate the inspection program as well. Feed the measurement station from a controlled source set near both nominal frequencies and check that the software stores the original hertz value and the actual acceptance band. A 1 ppm reference error represents roughly 156 Hz at this frequency. Use the agreed measurement decision rule when a result approaches a band edge. A counter's ability to display individual hertz and its absolute accuracy are different. Measurement uncertainty still cannot distinguish the order identities where the bands overlap.
If old entries are abbreviated, look up historical purchase orders and the manufacturer configurations originally approved. Keep fully traceable material distinct from stock that has only a rounded display value. Preserve the original output standard and board termination for alternate-source evaluation so a second variable does not enter the frequency comparison. A lab can simulate either nominal frequency for functionality. Receiving still needs evidence of the actual part delivered.
Tie release to the complete 156.250000 MHz part number and retain the six-digit frequency field, output format and allowed deviation. Ask for equivalent manufacturer evidence when qualifying another 156.25 MHz differential oscillator and have the assembler verify it under the approved clock conditions. The source record will preserve the frequency choice even when the report displays two decimal places.