A miniature oven-controlled crystal oscillator can hold its frequency on the evaluation board yet shift with processor load in the assembled system. The cabinet inlet may stay within specification while heat travels along the PCB copper to the oscillator. A chamber or cabinet sensor measures the air. The board can be considerably hotter at the oscillator’s mounting pads.
Record board temperature and frequency on the same time axis
In its Mercury and Mercury+ guidelines, Rakon notes that nearby heat sources can raise board temperature above ambient air temperature. The oven keeps its internal temperature steady by adjusting heater power. When it continuously absorbs external heat, it has only so much heater power left to reduce. Connor-Winfield’s layout note also calls for assessing heat conduction through multilayer boards, including heat from high-power devices next to the oscillator. Each document applies to its manufacturer’s products. For the actual part, ask the supplier whether the specified temperature range refers to the air, the case, or the mounting location.
Start by repeating a processor load step in the assembled system. After the agreed oscillator warm-up, hold cabinet airflow and power-supply settings constant. With the processor idle, log output frequency, board temperature near the oscillator, and supply voltage at the oscillator pins. Then apply a representative sustained load. Save traces that show any near-instant frequency change with voltage and any delayed change as the board warms. Both effects can occur in the same test, so timing alone cannot establish the cause.
What to tell the supplier before changing the layout
Send the supplier the board identifier, the mounting location, a photo of the temperature measurement point, the maximum sustained load, and the warm-up time. Ask which mounting board and airflow conditions were used for the published temperature-stability data, then decide whether to test in the assembled system. A dedicated fan can introduce additional temperature fluctuations. For the Mercury series, follow the manufacturer’s guidance when evaluating cooling. On the revised prototype, use the same load step to compare frequency offset and recovery time, and identify the measurement reference in your record. A tighter-tolerance part alone cannot show that heat transfer from the processor to the oscillator is under control.
Rakon Mercury and Mercury+ OCXO application guidelines · Connor-Winfield AN2093: layout and heat conduction through PCB layers