A synchronization device can show an occasional phase step while its hourly mean frequency error remains small. For maximum time interval error (MTIE), find the worst time excursion within the specified observation interval. Averaging positive and negative errors can hide a transient that affects downstream buffers and synchronization windows.
Find the highest and lowest point in each sliding window
Acquire continuous time error relative to the same reference. For one observation interval, take the maximum minus minimum in every available window, then take the largest of those ranges. In a sequence of 1, 2, 18, 3 and 2 ns, a window containing 1 and 18 ns spans 17 ns. Returning to 2 ns does not remove that recorded maximum.
Plot MTIE for each observation interval and compare at the same durations in the customer template. Do not average window spans or join points across a data gap. Mark intervals longer than the available continuous record as missing. Wide sampling intervals can also miss a short pulse entirely.
Retain the start and end of the maximum window and the original timestamps of its extrema. Correlate them with reference switching, thermal control or missed counter edges. That supports recalculation and investigation across device, system and measurement chain. A plot without time indices rarely locates a single event. Compare devices using comparable record lengths because longer captures are more likely to contain rare steps.Microchip 53100A phase and frequency stability analysis manual