A quote copies 0.34 ppm from the M625x front page into absolute frequency error. MtronPTI describes it as peak-to-peak holdover stability under specified conditions. Ordering option S instead lists ±4.6 ppm with Holdover and shows an example code. The figures have different references and definitions. A 0.34 ppm span does not put every reading within ±0.17 ppm of nominal.
Use three readings to distinguish span from offset
For illustration, readings of +1.00, +1.10 and +1.34 ppm relative to nominal span 0.34 ppm peak-to-peak, while the largest absolute deviation is +1.34 ppm. These are example numbers. Specify absolute error, comparison interval, pre-holdover calibration or lock, and temperature, supply and duration. If the requirement is accumulated time error, define its integration start and permitted error instead of replacing one ppm value with another.
Identify the configuration from the order code
The example M62512STCN code carries supply, voltage-control and tri-state, CMOS output and package fields. Ask which specification governs the actual frequency and full order code, without copying all the example limits to variants. Retain readings before and after calibration and continuous holdover data. A single counter photograph cannot establish an entire window's peak-to-peak value.
List the two metrics separately in contract acceptance, each with its reference frequency and window. If the customer asks for more stability, establish whether they need a better absolute starting point, less variation in holdover or lower accumulated time error. MtronPTI M625x specification and ordering examples