Repair sourcing for the NDK NT3225SA 40 MHz TCXO: which pin 1 is on the board?

A service quote gives NDK NT3225SA, 40 MHz and 3 V. The board has a DAC near the oscillator, and a technician may check that the output is near 40 MHz before investigating the rest of the unit. When replacing this 40 MHz temperature-compensated oscillator, establish what pin 1 does before taking that reading. In NDK's two historical drawings, the automatic-frequency-control version uses pin 1 for a control voltage. The fixed-frequency version allows that pin to be open or grounded, with ground recommended. Both drawings share the model name and nominal frequency. Ordering on those fields alone risks installing a fixed-frequency part in a board that relies on a control loop.

Identify the specification number at the voltage and frequency

NDK's AFC drawing lists NSA3630C for 40 MHz, with 3 V as the standard specification. The 40 MHz fixed-frequency drawing lists NSA3631C for 1.8 V and NSA3632C for 3 V. Include model, frequency and specification number in the order inquiry. Both drawings also place 38.4 MHz in the same specification groups as 40 MHz. Even NSA3630C on its own leaves the frequency unresolved. If an old label only shows the series or group, use the purchase confirmation, build record or original sample to establish the missing field.

NDK's discontinuation index gives the three AFC specification numbers their own entry, directs customers to contact NDK for timing, and lists no substitute there. The fixed-frequency row has separate recommended series information. Do not apply that row to a board that requires AFC. Ask for the original label, the actual proposed shipping lot, source documentation and samples. Check the lifecycle for the specific number with the manufacturer. A historical document establishes the configuration, while current orders or stock require separate evidence.

Determine what the original board does with pin 1

With power off, trace pin 1 to the nearby resistors, ground and the control circuit. Where drawing revisions are unclear, check the real routing and populated sites. On an AFC board with a DAC connection, record the pin voltage on start-up and after the loop locks. On a fixed-frequency board that grounds pin 1, an AFC candidate needs fresh review because ground lies outside the listed 0.5 to 2.5 V tuning interval. Keep a candidate on the bench until the original pin function is understood and verified.

One board revision may ground the pad through a link and another may route it to a control net after removing the link. Check the actual resistor site, any repair wires and firmware DAC behavior as well as the assembly number. If a service lot mixes both circuits, record the permitted specification against the board serials for each. Capture the control voltage relative to oscillator ground with the clock so the supplier's test conditions can be compared to the repair bench.

Check tuning range and direction after the first frequency reading

The historical AFC drawing lists a 1.5 V control center with ±1 V excursion and a ±9 to ±15 ppm control range. One ppm at 40 MHz equals 40 Hz, so that is on the order of ±360 to ±600 Hz. If the loop must correct at least 480 Hz in either direction, the requirement is ±12 ppm. The catalog's low end of ±9 ppm is 120 Hz short on either side. Ask the supplier for the applicable tuning requirements and guarantees for the sample, and capture low, center and high readings at the voltages the board actually supplies.

The specified output load is 10 kΩ in parallel with 10 pF, with 0.8 V peak to peak minimum output. The note says the oscillator has no internal DC-blocking capacitor and calls for an external 1,000 pF capacitor in the output line. Record the load, coupling arrangement and receiver bias on the bench. Suppose the board can reach only 0.8 to 2.2 V at the control pad. Its span is 1.4 V, or 0.6 V less than the full 2 V specification span. Measure the actual curve to find the usable range on each side. Pair each frequency observation with its control-pad voltage so that weak tuning can be separated from a board that cannot reach the voltage endpoint.

Record settling time during the sweep. If the control jumps between voltages, a counter can include both frequencies in a single gate. Wait for the control and output to settle, use the same gate for each reading, and recheck the center point for drift. Retain the first reading after cold start separately from the temperature-settled repeat. If the supplier provides a temperature sweep, confirm the fixed control voltage and whether that plot describes temperature stability or tuning range.

Attach purchase confirmation and sample results to each other

For a service order, put the confirmed model, frequency, specification number, board revision and pin 1 state on the material release. Keep the label and sample results in that record. Pause installation of a confirmed fixed-frequency 3 V part if the board needs AFC, even if it produced the right nominal clock at one point. If the quote identifies the correct AFC number but the correction range is still uncertain, approve samples first and accept the lot after the control sweep passes the loop requirement. The next repair can then recover both the specific configuration and the measured evidence.