Why verify beta when an NDK 38.4 MHz passive crystal's thermistor already reads 100 kΩ?

A radio board needs a replacement 38.4 MHz passive crystal with integrated temperature sensing. A supplier sample measures about 100 kΩ at room temperature and oscillates near the correct frequency. The team proposes reusing the old temperature conversion. NDK's NX1612SD sheet specifies both the resistance at 25 °C and a beta value between 25 and 50 °C. Matching room-temperature resistance can still leave a different temperature curve. Verify both crystal and sensor connections and compare ADC results in the chamber. Room-temperature component readings are useful as part of the approved conditions.

Check the two circuits in the package separately

NDK specification NDKX02-00004-004 lists 38.400 MHz for STD-CTI-2. It specifies 8 pF load capacitance and a 50 Ω maximum series resistance from 38.4 MHz to below 52 MHz. Its pin diagram identifies pins 1 and 3 for the crystal, pin 2 as thermistor output and ground, and pin 4 as thermistor input. The manufacturer page calls for model, frequency, and specification number when ordering. Record these with the package-view orientation and sensor connections. A library rule that grounds both pins 2 and 4 for a plain four-pad crystal must be changed before using the thermistor channel.

The nominal resistance is 100 kΩ at 25 °C with ±1% tolerance. The nominal beta is 4,250 K with ±1% tolerance, specified at 25 and 50 °C. If an offer gives only 100 kΩ, request the beta, temperature points, and applicable drawing. Obtain resistance-temperature data as required for the intended range. Avoid treating a two-point parameter as an exact characterization at every temperature. A different thermistor crystal can be evaluated as a candidate with its own specification. Obtain any required qualification records for the exact order as well.

Compare nominal resistance at 50 °C

In a common thermistor approximation, take the difference of inverse absolute temperatures, multiply by beta, exponentiate, and multiply by resistance at 25 °C. Using 298.15 K and 323.15 K, 100 kΩ and a beta of 4,250 K gives about 33.19 kΩ at 50 °C. A hypothetical candidate with the same room-temperature resistance and a 3,950 K beta over the same points gives about 35.88 kΩ. The second beta illustrates the comparison and is not an NDK variant. A 1.8 V divider with a fixed 100 kΩ upper resistor and the thermistor below produces 0.9 V nominally at 25 °C for both. At 50 °C, it gives roughly 0.449 V and 0.475 V, a difference of about 27 mV. A single room-temperature calibration cannot establish equal readings at the second point.

Those results use nominal inputs. Include tolerance and test current in actual inspection. Continuous divider current could cause self-heating. Measure at an appropriate low power, let the specimen stabilize, and record actual temperature before repeating. For an assembled board, retain the original resistance or ADC code and the converted temperature. If the board conversion drifts between the two points, a controlled check with known resistors can separate the sensor from pullup, reference-voltage, and software effects. Keep graphs connected to the specimen and exact specification.

For a supplier and incoming lab to compare the same resistance test, move one specimen through both temperature points. Divide its 25 °C reading by its 50 °C reading, take the natural logarithm, and divide by the difference in inverse absolute temperatures to recover the two-point beta. Use measured temperatures and account for instrument uncertainty. Averages from different specimen groups do not give the beta of one part. If the supplier reports only a lot average, establish its sample count, available lot-to-lot information, and traceable raw data before designing the incoming sample plan.

A chamber sensor far from the fixture can reach its setpoint before the specimen. Improve sensor placement or allow additional stabilization when the sample temperature is uncertain. Rotate a verified reference part through the same fixture to check for setup changes. A temperature-control discrepancy calls for a fixture retest. A repeated deviation after both points stabilize can support a supplier review under the agreed conditions.

Verify both the crystal and temperature channel before release

During a pilot build, compare the approved and proposed 38.4 MHz passive crystals on the same fixture for frequency, load, and applicable resistance. Then compare the mounted sensor at both points and measure the compensated board frequency through the intended range. The integrated sensor measures closer to the resonator, but the board implements compensation. If existing firmware uses coefficients for only the original type, approve and identify any new coefficients by board revision. A per-board calibration also needs a way to save and recover its values.

Frequency and room-temperature resistance reports each belong in the record. Release also depends on whether the system uses the sensor channel. For a replacement in a compensated design, list model, frequency, NDK specification, and resistance and beta conditions. Hold unresolved beta or temperature data for a controlled engineering trial. Issue material against the approved version when part identity and measurements conform. Repair then has a record of both the sensor crystal and the board settings. Retain fixture, bias, and thermometer information so the next supplier comparison has a reliable baseline.