A purchasing engineer sees 50 Ω in the NDK NX3225GA data sheet. A sample of the 10 MHz crystal also starts on the existing board. Can the team put 50 Ω on the approval record? First find the frequency band attached to that number. NDK uses one standard specification for several frequency bands, with different equivalent-resistance limits. The 10 MHz configuration covered by this standard specification is rated at up to 200 Ω. Whether it suits the board depends on the loss the oscillator circuit can tolerate under the corresponding conditions.
Read the specification number and frequency together
On page 2 of NDKX03-00006-004, the equivalent-resistance row refers to Table 1. Confirm that the quote identifies standard specification STD-CRG-2, then locate the exact nominal frequency. Pay particular attention to the breakpoints.
| Nominal frequency | Maximum equivalent resistance |
|---|---|
| 9.8 MHz to below 12 MHz | 200 Ω |
| 12 MHz to below 13 MHz | 100 Ω |
| 13 MHz to below 20 MHz | 80 Ω |
| 20 MHz through 50 MHz, inclusive | 50 Ω |
Page 3 lists both 11.852625 MHz and 12.000 MHz as supported frequencies. The 11.852625 MHz entry maps to a 200 Ω maximum and the 12.000 MHz entry maps to 100 Ω. Rounding the first frequency to “12 MHz” would put it in the wrong band. The table also lists 10 MHz. An 8 MHz requirement is below the stated range of this standard configuration; obtain a corresponding specification before assessing its resistance and load capacitance. The supported-frequency list does not establish current stock or a delivery commitment.
What a 90 Ω sample tells you about a 200 Ω specification
A resonator dissipates some energy as it vibrates. As the oscillator starts, the active circuit must make up that loss for the signal to build. A low-resistance sample can therefore start more easily in the same circuit. Suppose the MCU vendor allows a maximum crystal equivalent resistance of 120 Ω at 10 MHz for the selected drive setting, load and minimum voltage, and confirms that its resistance criterion is comparable to the crystal specification. A 90 Ω sample measures 30 Ω below that limit. The standard 200 Ω crystal guarantee is still 80 Ω above the board's allowance. The margin on one low-resistance sample provides no guarantee for the next lot.
If 120 Ω is a firm circuit constraint, ask for a manufacturer specification tied to the full ordering code that guarantees 120 Ω or less. Confirm the frequency, measurement conditions and applicable temperature of that guarantee. If no suitable specification is available, engineering can review the oscillator configuration or evaluate a crystal with a documented limit. Sampling several parts can support incoming inspection. It cannot make the standard 200 Ω limit into a 120 Ω guarantee.
How the manufacturer estimates start-up capability
NDK uses negative resistance to describe the oscillator circuit's ability to compensate for losses. Its measurement procedure inserts a resistor in series with the crystal and varies it to find the start-up boundary. Follow the manufacturer's sequence to identify the point where the signal reappears. Under that procedure, the magnitude of the circuit's negative resistance is estimated by adding the external resistance at the boundary to the crystal resistance under the applicable measurement conditions.
For example, assume a 410 Ω series resistor at the specified restart boundary and 90 Ω crystal resistance under comparable conditions. The estimate is 500 Ω. If the maximum crystal loss to evaluate is 200 Ω on the same basis, the difference is 300 Ω and the ratio is 2.5. Those figures describe this example at one set of conditions. Compare them with the guidance for the actual MCU and crystal and with results across the board's temperature and supply range. Changes in drive setting, capacitance or supply require reassessing the result.
Capture the interval from a complete power-off condition to a valid clock. Watching a running oscillator stop and checking its ability to restart can produce different thresholds. Test relevant cold-start and low-voltage conditions, monitor start-up time, and measure crystal drive in normal operation. Where the MCU provides a buffered clock output, it can help observe operation without loading the oscillator pins. A higher drive setting can help start-up, but frequency and crystal dissipation still require verification.
What purchasing and engineering should approve
The same standard specification gives an 8 pF load and an operating temperature range of −40 to +85 °C. A different load option needs the corresponding ordering specification. On the inspection record, identify the fixture, drive and definition of the reported resistance. NDK's table refers to the IEC π-network and series measurement. Align the oscillator test's loss calculation with the conditions and definitions in the MCU data. Purchasing can then require a verifiable limit on the ordering record, while engineering records the supply, load, drive and start-up conditions that it accepted. If a lot later fails to start, these records provide three concrete places to check: the ordered configuration, the electrical measurement and the state of the board.
The NDK sheet also has two distinct frequency limits. At 10 MHz, its ±20 ppm initial tolerance at 25 °C corresponds to ±200 Hz. The ±30 ppm temperature characteristic is referenced to 25 °C, so it permits a further 300 Hz departure from a specimen's room-temperature reading. A worst-case sum covering just those two terms is ±500 Hz when the other conditions hold. Load mismatch and other errors need separate entries in a board budget. A board that starts reliably still needs a frequency check at its intended load and operating conditions.
A typical resistance on a quote is not an acceptance limit. Agree on the maximum, the sampling rule and how to repeat measurements near the limit. A reading of 118 Ω against a 120 Ω requirement calls for the agreed decision rule and measurement uncertainty, rather than an unexplained pass based on the displayed digits alone.