The player claims to have switched to 48 kHz, but the logic analyzer still shows 44.1 kHz at LRCK. A board that retains its 22.5792 MHz source and divides by 512 will do exactly that. Identify the source of the actual frame clock before choosing between a clock-tree change, an additional oscillator, and rate conversion in the data path.
Capture a complete set of rates in each mode
Suppose the project uses a 512-times system clock for both rates. A 44,100 Hz frame rate requires 22,579,200 Hz. A 48,000 Hz frame rate requires 24,576,000 Hz. Deriving exactly 48 kHz directly from 22.5792 MHz would require division by 470.4. The nearest integer divisors, 470 and 471, give about 48,040.85 Hz and 47,938.85 Hz respectively. Keeping the original divide-by-512 gives 44,100 Hz. These are calculations for a hypothetical clock path. Check the actual architecture and register readback for the board.
For example, TI PCM1808 Table 1 lists 256, 384 and 512 times the sample rate for both 44.1 and 48 kHz. At 256 times, the corresponding system clocks are 11.2896 and 12.288 MHz. This is one reason to examine supported ratios before requesting a part. Capture MCLK, bit clock, frame clock and data in both operating modes. Locate the signal at the active receiver and identify which component drives it. The frequency observed at the oscillator can remain unchanged while an output is switched internally. TI PCM1808 system-clock and sample-rate table.
Choose a clock architecture before ordering another part
If the device needs native operation in both families and accepts separate clock sources, switching between 22.5792 and 24.576 MHz is one architecture. Check the clock selector, enable timing and signal levels. Measure when the frame clock actually reaches the new frequency. The mathematical ratio between those references is 160/147. A fractional synthesizer may generate an appropriate clock, provided its input divider, internal and output ranges, lock behavior, phase noise and spurs all meet the requirements. For example, the PCM512x PLL generates internal clocks and has configuration-dependent constraints on its divided input and internal clock. That does not establish that another device on the same board will receive an external frame clock. TI PCM512x PLL settings and clock limits.
Another architecture keeps one hardware rate and converts the data before it reaches that interface. In that design, LRCK need not follow the source file's nominal sample rate. Check the conversion settings, channel mapping, reproduced tone and amplitude, and long-running buffer operation. If a product requires bit-transparent output or matching input and output rates, carry that requirement into the architecture decision. A final listening test should use known data and the intended path, including any conversion.
A one-second test file can help distinguish these cases. Suppose 48,000 input samples are sent directly at 44,100 samples per second. That material runs for about 1.0884 seconds. A 1 kHz tone represented by those samples then plays at about 918.75 Hz. After correct sample-rate conversion, the one-second signal still lasts one second, with the tone near 1 kHz. Compare elapsed time, measured pitch and the hardware frame rate together. This distinguishes working conversion from playing unchanged samples at the old hardware rate or merely updating the status display.
Troubleshoot a pop as a timed transition
If both steady states are correct but switching produces an audible pop, capture the mute signal, old and new clocks, lock or ready indication, resumed data and unmute on one timeline. Follow the specific converter's mute and start requirements. Test the switch in both directions and record what happens at cold startup as well as when both clocks are already running. Give purchasing the selected reference frequency or frequencies, exact order codes and electrical conditions. The bench qualification should show the actual frame rate in each mode, plus the sequence that produces a quiet transition.