RTC module: how to tell whether losing main power costs one count

After losing and regaining power, the RTC calendar appears one second behind. If the software saved only two readings rounded to whole seconds and one read coincided with a carry, it is hard to distinguish interrupted counting, read latency, and display rounding.

Make the calendar snapshots comparable

Read hours, minutes, and seconds using the model's burst-read or snapshot mechanism. If the IC has no snapshot, use the consistency check supported by its manual. Record the start and end of each read and capture an external reference timestamp for both power loss and restoration. Follow the manual for when bus access may resume after power returns. Epson RX8900SA manual, Sections 8.8, 8.9, and 8.11

Capture main power, backup power, and reference second edges on the same time axis. Change when power is lost relative to the second edge and repeat the transition. Save oscillator-stop or clock-valid flags and record when they were read and cleared. If the flags indicate an oscillator interruption, investigate supply changeover and backup voltage. If the symptom occurs only on reads that span a second boundary, check the driver first.

Compare accumulated error over a longer observation window. A difference that grows by nearly one second at every changeover and then persists differs from an instantaneous one-second difference on the display. For the former, retain power waveforms, calendar snapshots, and timestamps to reproduce the issue.