1920 × 1080 × 60 equals 124,416,000. This counts the active pixels per second only. A video interface with blanking can transmit line sync and blanking intervals before it begins carrying visible pixels, so the active pixel count alone is insufficient for specifying the oscillator.
Count the intervals in one line and one frame
Assume one pixel per clock. The active interval, front porch, sync pulse, and back porch together occupy 2,200 clocks per horizontal line. The vertical intervals add up to 1,125 lines. Each frame therefore takes 2,475,000 clocks. At exactly 60 Hz, the pixel clock is 148.5 MHz. If the specification instead gives a frame rate of 60 000/1 001 frames/s, recalculate with that exact ratio and the same totals.
Check which pin takes the clock before requesting a quote. A parallel interface that transfers two pixels per cycle requires a different bus clock. A device with a PLL may derive its pixel clock from a separate external reference. Record the total clocks per line, lines per frame, frame rate, pixels per clock, PLL ratio, and external reference requirements in the mode table. Use the receiver specification to determine the differential signaling standard.