Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

12 MHz crystals: handing board-level tuning results over to purchasing

“The prototype is on frequency. We can buy the 12 MHz crystal from a second source.” Before that statement becomes a purchase order, find out which board, capacitor pair and firmware setting produced the result. If the alternate only works after a capacitor change, releasing the crystal alone as a substitute allows production to build a combination that engineering never qualified.

Identify the crystal and the validated assembly separately

NDK's NX3225GA with standard specification STD-CRG-2 provides a concrete way to read a part record. Its frequency table includes 12.000 MHz. The standard part uses fundamental mode and an 8 pF load. Exactly 12.000 MHz lies in the band from 12 MHz up to, but excluding, 13 MHz, which gives a maximum resistance of 100 Ω. The document separately gives initial tolerance at +25 °C, temperature behavior and drive. NDK asks for model, frequency and specification number when quoting or ordering. Verify actual packaging and lot requirements with the quotation and approved samples. NDK NX3225GA standard specification, pages 2 and 3.

  • Crystal record. Keep the manufacturer, complete ordering details, 12.000 MHz, approved specification revision, specified load, resistance limit, temperature range and drive. Identify the initial tolerance and temperature rows separately.
  • Assembly record. Keep the PCB and schematic revisions, host part number, crystal reference designator, and both capacitor positions, fitted values and tolerances. Mark the unused oscillator positions as do not populate.
  • Firmware and acceptance record. Store the oscillator mode, internal capacitance or drive setting, supported test point and actual clock division. Record frequency and startup under the temperatures and supply conditions required by the project. Link the acceptance record to the release line.

Read the results as complete configurations

Suppose the original crystal specifies an 8 pF load. The example has a pair of 12 pF external capacitors and an estimated 2 pF of terminal-equivalent parasitic capacitance, for a total load near 8 pF. Suppose the alternate is specified at 10 pF. Test the alternate first with the existing assembly, and then with a pair of 16 pF capacitors. The same model estimates 10 pF for the latter combination. A host with internal load capacitors needs its own model. Measure both candidates on the actual board. ST AN2867, load and startup considerations.

Suppose the project allows ±20 ppm of board frequency error at room temperature and requires a usable clock within 20 ms under the stated cold-start condition. The original combination reads 12,000,048 Hz, or +4 ppm, and starts in 14 ms. The alternate with unchanged capacitors gives 12,000,360 Hz, or +30 ppm, and starts in 13 ms. With the two 16 pF capacitors, it gives 12,000,072 Hz, or +6 ppm, but starts in 28 ms. The three results are hypothetical. The untouched board fails the frequency condition with the alternate, and the retuned board misses startup. Review drive margin, power ramp, and the candidate's resistance before choosing the next test. The acceptance sheet should have room to record both measurements.

Release the part and its conditions together

If later tests support both configurations, maintain them as qualified combinations in the production BOM or approved alternate list. The original crystal can use the tested 12 pF pair and the second-source part can use its own validated pair, with the approved firmware and product variants tied to each. If the procurement system allows only a single-item alternate, use the assembly work order or engineering change to make the associated capacitor change traceable. A frequency reading from one prototype is a useful screening result. Production approval needs repeatable frequency and startup evidence for the agreed board, lot, supply and temperature conditions.

At first-article inspection, have production identify which approved combination was fitted before comparing measurement records. A result without the board revision, flashed image and fitted capacitor positions cannot settle a discrepancy between an approved prototype and an incoming lot. Ask the line to keep those records alongside the crystal lot identifier.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.