Start a low-power budget by tracking charge per hour. Suppose the oscillator runs at 2 mA for 6 minutes and stays in standby at 10 µA for the remaining 54 minutes. The running charge is 2 × 0.1 = 0.200 mAh and standby uses 0.010 × 0.9 = 0.009 mAh. The total is 0.209 mAh in one hour, corresponding to 0.209 mA average. Over 24 hours, the same pattern consumes 5.016 mAh.
Do one long wake-up and many short wake-ups use the same charge for six minutes of run time?
Changing the schedule from one run per hour to one per minute increases the number of starts by a factor of 60. Multiply the extra charge per wake-up, from oscillator startup through PLL lock, by the number of starts and add it to the steady-state budget. If current has already been integrated over the complete cycle, it already includes startup and must not be added again.
Capture supply current and the wake signal together. Choose a range that can resolve standby current without clipping the startup peak. Battery-life estimates must also include other system loads and regulator losses. The 5.016 mAh example covers only the oscillator's assumed steady-state schedule.