If a multimeter reads 3.2 V after disabling OE, that reading alone does not establish that the oscillator is still driving the node. Check how the exact part defines OE polarity and its disabled output. Some configurations go high-impedance, leaving external pull-ups, pull-downs, and leakage to determine the pin voltage.
What can one 10 kΩ pull-up tell you?
A 10 kΩ pull-up to 3.3 V with 10 µA of net leakage to ground drops about 0.1 V, leaving the node at about 3.2 V. If a separate pull-down path nearly shorts the node to ground, pull-up current can approach 3.3 ÷ 10,000 = 330 µA. The estimates describe different loads. The OE logic level alone does not tell you the current.
Change the external bias within the IC's permitted conditions and observe whether the disabled node follows it. Record the time from the last output edge to steady state so capacitor charging or discharging does not distort the reading. Restore the production bias and verify the receiver level while disabled and the clock after re-enabling.