Two quotes may both say “100 MHz HCSL” and the board may already have termination resistors. To decide whether to reuse them, establish how the driver supplies current, what the receiver has internally, and at which end the resistors are populated. An oscillator part number alone describes only one end of the circuit.
Include the receiver in the schematic sent with the RFQ
| What to show on the schematic | What to decide from the information |
|---|---|
| Full oscillator ordering code and output stage type | Check the connection diagram for that output option. Conventional HCSL and LP-HCSL can use different networks. |
| Receiver model and actual input mode | Confirm whether the receiver has internal termination and check the swing and common-mode requirements for the selected mode. |
| Resistor locations and populated values at both ends of the PCB | Check for redundant termination and missing components. Distinguish unpopulated footprints from fitted resistors. |
After powering the first sample, measure the waveform at the receiver pins. A 100 MHz counter reading shows that it detected edges. For PCIe, also verify jitter against the target generation and reference clock architecture, and record link training and operation under load.
SiTime's application note shows termination circuits by output type and can help identify the circuit the supplier uses. SiTime differential oscillator termination guidance