A development board may have been used to try several SiTime MEMS oscillator configurations. A sample box labeled with only the series name cannot tell production purchasing which frequency, output drive, and enable settings passed. Link the approved configuration file or supplier confirmation to the board ID, sample label, and test report.
Turn the programmed sample into a production order code
From the options supported by the exact device, record nominal frequency with its unit, supply, output interface, drive setting, temperature range, and enable behavior. Place the supplier’s production order code alongside them and decode it using the applicable ordering rules. Two parts at the same frequency can use different output drive strengths or OE behavior, so earlier transition or standby measurements may no longer apply.
For the first incoming lot, recheck frequency and edge behavior under the same board load. Toggle enable and record the output state. If the product will enter sleep, measure the time to a valid clock after wake-up. Approve both the tested order code and the configuration revision. Future codes can be compared field by field to determine which checks to repeat.