Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Packages and Board Assembly

5032 crystal packages: defining a keepout near a metal can

When a 5032 metal-can device sits close to a shield, identify the metal feature nearest the shield. The side of the can, the base connection, and the terminals may have different electrical functions. Reorient the manufacturer’s bottom-view drawing to match the PCB view and mark each signal connection, case connection, and pin with special requirements.

For pins marked NC or DNC, follow the manufacturer’s explicit instructions for the exact pin. Some pins must be left floating, while case connections may have their own specified connection. Grounding everything can hide those differences. If the drawing supplies only the outline, obtain the pin table for the exact part.

Check the installed clearance from three views

Use a section view for can top to shield underside, a plan view for can side to stud or spring contact, and a bottom view for underside metal to PCB copper. Account for the maximum part height, placement tolerance, and shield assembly tolerance. Fit the shield with power off on the tallest sample and the sample closest to the edge. Check continuity and look for rub marks. Record the minimum measured gap on the mechanical drawing.

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.