7.3728 MHz crystals: why UART baud rate can halve with the correct reference frequency

If the UART works normally before sleep but the remote endpoint must switch from 57600 to 28800 baud after wake-up to receive data, first capture the registers before and after wake-up. Reinitializing the port can erase evidence of which clock source changed.

16× oversampling, divisor of 8UART inputCalculated baud rateApproximate bit duration
Direct reference clock7.3728 MHz5760017.36 µs
Bus prescaled by two3.6864 MHz2880034.72 µs

Send repeating characters with alternating bits on TX and measure bit width using the data edges. If the reading matches the second row, trace the UART clock selection upstream and check the bus prescaler, clock source and oversampling configuration on wake-up. The prescaler in the table is one possible cause. Changing the oversampling setting can also produce an integer-factor difference.

Give the firmware engineer a side-by-side record of register values and measured bit widths in normal operation and after wake-up. If only the remote endpoint decodes incorrectly while the local bit width remains close to 17.36 µs, check the remote clock, data bits and stop bits before repeatedly replacing the 7.3728 MHz crystal.

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.