After a solvent change, several boards show slow cold startup. Testing the new-process group once gives little basis for finding the cause. First check the part’s restrictions on solvents, cleaning equipment, and ultrasonic methods. Within those limits, divide parts from the same incoming lot into three groups: old cleaning process, new process, and no cleaning. Give every sample its own ID.
Calculate the before-and-after difference for each part
Before cleaning, measure each part’s frequency and startup time at the same temperature, load, and power-on conditions. Repeat under the same conditions after cleaning and match the records by sample ID. Have the uncleaned group go through the same waiting and measurement steps to expose any time-dependent changes in the environment or fixture. A comparison of post-cleaning group averages alone also includes the parts’ original variation.
Record the solvent, equipment, temperature, duration, and drying conditions. If ultrasonic cleaning is used, also record the equipment settings. If normal operation returns after thorough drying, investigate residue and leakage at high-impedance nodes. If the anomaly persists, check solder joints, vibration, and the part itself. Keep the evidence for each check before deciding whether to change the process.