“Loses less than one minute a year” is already a tight clock requirement. A 365-day year of continuous operation has 31,536,000 seconds. A 60-second error corresponds to an average absolute frequency deviation of about 1.90 ppm. The initial timekeeping error, seasonal temperature variation, and aging all need allocations in this budget.
How long can it go without a valid time synchronization?
If a device normally connects daily but must tolerate 30 consecutive days offline, the acceptance window must cover those 30 days. For example, an allowed error of 5 s over 30 days is equivalent to 1.93 ppm. Any error remaining after the last synchronization reduces the amount available for offline drift.
During specification review, put the allowed accumulated error, maximum time without synchronization, initial error after calibration, and ambient temperature range on the same line. If a passive-crystal design needs calibration per unit, budget the labor. If a temperature-compensated RTC must keep time on a coin cell, check the backup current. Each cost follows from a different operating requirement.