If the system specification simply says “100 MHz, allowable error 80 Hz,” determine whether this is an absolute limit from shipment to end of life or a limit at a particular test temperature. An absolute lifetime limit leaves only 0.8 ppm for all error contributions combined.
| Example candidate specifications | Convert to hertz | What still needs to be established |
|---|---|---|
| Candidate A: ±0.5 ppm maximum variation over temperature | ±50 Hz | When adding worst-case errors, is the remaining 30 Hz enough to cover initial tolerance, supply sensitivity, load sensitivity and aging? |
| Candidate B: ±0.7 ppm maximum total stability | ±70 Hz | If the guarantee covers the same temperature range and service life, 10 Hz remains. If aging is excluded, allow for drift over the product's service life. |
Include the datasheet footnotes when comparing quotes and match each error source to its guarantee. Avoid counting a contribution again if the supplier includes it in the total. Mark undefined contributions for follow-up. Compare remaining margin in hertz once the temperature range, supply range and service life match. Example of separate temperature, voltage and aging limits in a Taitien specification