A board has a 25 MHz crystal. As soon as the scope probe touches a crystal pin, the displayed frequency is lower than the firmware reading. Before retuning the board or rejecting the crystal, keep a second measurement running elsewhere on the circuit. That measurement can show whether the clock itself moves when the probe is attached.

How much load does an 8 pF probe add?

Assume that each crystal pin has a 16 pF branch to ground and that all other parasitics remain fixed. The two branches contribute 16 × 16 ÷ (16 + 16) = 8.0 pF to the load seen between the crystal terminals. If a probe adds an equivalent 8 pF to ground at one pin, that branch becomes 24 pF. The two branches now contribute 16 × 24 ÷ (16 + 24) = 9.6 pF. The estimated increase at the crystal is 1.6 pF. The probe is connected from a pin to ground, so its entire 8 pF does not go directly across the crystal.

Try the same calculation with a hypothetical 1 pF probe. One branch becomes 17 pF, and the result is 16 × 17 ÷ 33 ≈ 8.242 pF, an increase of about 0.242 pF. If you put an 8 pF probe on both sides at the same time, each branch becomes 24 pF and the series contribution rises to 12 pF, which is 4 pF above the base condition. A two-channel measurement can change both branches. This estimate treats the probe inputs as capacitances to ground. Actual loading also depends on input resistance, the ground connection and the interaction with the oscillator amplifier.

Suppose a separate experiment around the original load establishes a local pulling slope of −9 ppm per pF. The 1.6 pF increase would move the frequency down around 14.4 ppm, or 360 Hz at 25 MHz. The 0.242 pF increase would correspond to about 2.2 ppm or 55 Hz. These are example estimates to guide measurement selection. Use the pulling characteristic of the selected crystal or characterize it on the board. A slope determined near one load should not be extrapolated over a large change.

Keep a counter on the buffered output

Configure a supported output to show the reference clock, and read back its source and divisor. Connect a counter to this output and leave its reference and wiring in place for all three readings. Record the frequency without a crystal-pin probe, with the probe attached, and after removing it. Give all readings time to settle. If the buffered output moves when the probe makes contact and returns when it is removed, the clock circuit itself has been disturbed. If only the scope's own frequency reading changes, look at the trigger, input amplitude, acquisition settings and the two instruments' time bases.

For example, a divide-by-four output might show 6,250,005 Hz before contact, then 6,249,915 Hz, and finally 6,250,004 Hz after removing the probe. A 90 Hz change at the buffered output corresponds to 360 Hz at the reference. The restored reading is within 1 Hz of the starting value. That last comparison is meaningful only if the measurement can resolve such a difference and repeat it. If the available reference or the chosen counter gate limits the test to tens of hertz, run repeat measurements at stable temperature and record the actual precision of the setup. State the divider in the report so no one interprets 90 Hz as the raw crystal shift.

What to record when the pin waveform matters

Use the chip maker's instructions to choose a supported test node. Select a probe with appropriate input capacitance, resistance, attenuation, signal range and bandwidth. For a direct measurement on a suitable node, keep the ground connection short and local. Ground-lead inductance can interact with the probe capacitance and alter the displayed waveform. Document the actual probe configuration. Bandwidth alone gives little information about how much current a probe draws from this oscillator node. Verify the probe and scope settings before comparing revisions or using the traces to choose a part.

When comparing two probes, repeat the complete attach-and-remove sequence for each one. Start both trials from a fresh buffered baseline. Record whether the buffered clock changed, along with the displayed pin waveform. If two benches have used different connections, reproduce both methods on the same known-good board before attributing a frequency difference to the component lot. Keep the probe-off reading in the report so readers can distinguish the original operating point from the instrumented one.

If cold starts fail only with the probe connected, keep the unprobed startup results and the probed diagnostic tests in the record. For incoming inspection, use agreed crystal fixture conditions and the specified load. For board checks, use the verified buffered point wherever possible. If a receiving report says a lot runs low, purchasers can ask for the measurement node, fixture load, counter reference and the before/after probe readings. Those details help decide whether to request a supplier recheck or route the problem to the board team. Epson oscillator circuit and load guidance · Tektronix application note on probe loading.