A quote lists “5 ppm typical” frequency tolerance, and ten engineering samples all measure within ±4 ppm at room temperature. Before setting an automatic incoming rejection limit at ±5 ppm, locate the guaranteed limit accepted by both parties. A typical value and the extremes of ten samples do not set a limit for the entire lot.
Put the three types of figures in their proper fields
For the quote, record the complete order code, typical value, and its test conditions. For the samples, retain each unit's result, test temperature, and instrument. For acceptance, use the approved specification's maximum tolerance, reference temperature, and supply and load conditions. If the supplier offers a tighter grade, confirm that both the quote and samples are for that grade.
Suppose a sample measures +5.3 ppm at 25 °C. The disposition depends on the agreed maximum at that temperature, the capability of the measurement setup, and the applicable decision rule. Without a guaranteed limit, document the result as an observation and request confirmation. If the project requires ±5 ppm, choose an ordering option with that guarantee or document the screening conditions, method, and delivery records in the agreed specification. Epson: example frequency specification for a specific ordering code