Dividing 3.2768 MHz by 100 yields exactly 32.768 kHz. The divider produces a driven logic signal with defined voltage levels. Before feeding it to an RTC, consult the RTC's external-clock wiring diagram to identify the input pin, how to handle the other crystal pin, and the required configuration. Wiring it like a passive crystal can select the wrong operating mode.
What still provides those 32,768 clock cycles when main power is off?
Trace power separately for the reference source, divider, any level shifter, and the RTC. Even with a healthy RTC backup battery, loss of main power at any upstream stage can stop the input clock. If the external source stays on, check whether the RTC allows external drive while operating from backup power.
With main power on, measure the input high and low levels, duty cycle, and pulse width. Then capture the changeover from main to backup power, record the oscillator-stop flag, and read the calendar after a known interval. These checks cover continued timekeeping across a power outage better than a single 32.768 kHz counter reading while main power is on.