A 19.2 MHz TCXO that reads 12 Hz above nominal at the high-temperature point has not necessarily exceeded its temperature stability limit. If the specification defines stability relative to a particular reference temperature, first see how far the frequency at that point was already offset.
| Example readings | Relative to the nominal 19.2 MHz | Relative to the reading at the reference temperature |
|---|---|---|
| 19,200,006 Hz at the reference temperature | +6 Hz | 0 Hz |
| 19,200,012 Hz after stabilizing at high temperature | +12 Hz, approximately +0.625 ppm | +6 Hz, approximately +0.313 ppm |
A ±0.5 ppm temperature stability limit corresponds to ±9.6 Hz. With the reference point defined above, the change between these two readings lies within the band. If the system also requires the absolute error to remain within ±9.6 Hz, the high-temperature reading fails. Qualification over the full range must still cover the agreed temperature profile. Two points describe only the change between them.
Once the chamber temperature settles, check that temperature near the part and its output have stabilized, and retain the raw reference reading. The purchasing specification should state the budgets for initial calibration and temperature variation, or specify which combined guarantee applies. Example Epson TG2520SMN datasheet for a specific ordering option