Oscillator A specifies phase noise at 10 kHz from the carrier, while B specifies it at 100 kHz. Even if B's number is more negative, those two values do not establish which is better. Overlay the curves for the same carrier frequency and offset scale, then examine the band to which the system is most sensitive.
How to choose when the curves cross
If A is quieter close to the carrier and B is quieter farther away, check the receiving system's or downstream loop's noise transfer. If only several offset points matter, compare each with its limit and state whether the value comes from a typical curve or a guaranteed maximum. If RMS jitter across the band matters, the ranking at one point does not settle it.
Single-sideband phase noise L(f) is given in dBc/Hz. Before integrating, convert it to a linear power ratio, 10 raised to L(f)/10, and sum over the frequency intervals. Equal widths on a logarithmic plot can represent very different bandwidths in hertz. When using a calculator, record the carrier, single-sideband convention, integration limits, and treatment of spurs. If either supplier lacks a curve across the integration band, request the missing spectrum or a result over the same bandwidth. SiTime phase-noise calculator