Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

10 MHz frequency reference: how long should the gate stay open in direct counting?

Feed a 10 MHz signal to a direct counter. If it counts N cycles over a fixed gate time T, the frequency estimate is N/T. Counting one cycle more or less contributes a different error at each gate length.

Assumed gate time TFrequency increment per countEquivalent at 10 MHz
0.1 s10 Hz1 ppm
1 s1 Hz0.1 ppm
10 s0.1 Hz0.01 ppm

Extending the gate to 10 seconds helps with steady-state comparisons, but it averages frequency changes over that interval. When investigating cold-start overshoot, establish how long the anomaly lasts and set an acquisition interval on that time scale. A long gate covering both a fast and a slow segment can return an apparently normal reading.

Use the instrument manual to distinguish direct counting from reciprocal counting. Reciprocal counting measures the time occupied by complete input cycles and has a different resolution model. Record the gate setting and individual timestamps. Include timebase and trigger errors when assessing borderline samples. Keysight: principles of direct and reciprocal counting

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.