At exactly 12 MHz, choosing one KDS DSX321G drawing can give the wrong enclosure clearance. The Chinese catalog places 12 MHz and below in the 0.85 ± 0.15 mm group, giving a maximum of 1.00 mm. A Japanese catalog places 12 MHz and above in the 0.75 ± 0.15 mm group, giving a maximum of 0.90 mm. The resulting 0.10 mm difference depends on which range includes 12 MHz.KDS catalog in Chinese · KDS catalog in Japanese
Which drawing should govern acceptance?
First freeze the quoted full order code, frequency, suffix, and intended grade. Ask the supplier for the controlled drawing for that exact configuration. If the available clearance falls between the two limits, the smaller value alone is insufficient for approval. Once the specification is confirmed in writing, account for installed height after soldering and assembly tolerances.
Apply the same method to electrical tables. When recording maximum ESR, keep the full frequency band and its boundary symbols. Check the load, temperature range, pin functions, and notes. Retain the document date, page, row, and column conditions in the internal approval record so the next buyer can see exactly which configuration was covered.