Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Differential Signaling and Measurement

125 MHz LVDS oscillators: estimating current with an existing receiver termination

A board with a 125 MHz LVDS oscillator sometimes fails to lock after power has been removed, yet works after a warm reset. Compare the two starts at the receiver pins. At the moment of the failure, check for a valid differential clock and establish whether the receiver was powered, biased and ready to use it. The voltage examples below are hypothetical. The identified component specifications appear separately.

Two different readings can both be called 350 mV

At the receiver, measure P and N at the same instant and with the same reference. If P is 1.375 V and N is 1.025 V, the differential voltage P−N is +350 mV and the common-mode voltage (P+N)/2 is 1.20 V. On the opposite logic plateau, exchanging the two voltages gives −350 mV differential and the same 1.20 V common-mode level. The differential peak-to-peak swing across the two plateaus is 700 mV.

On the first plateau a 100 Ω resistor connected from P to N carries about 3.5 mA. The current reverses on the other plateau. A scope reading of 350 mV peak-to-peak on a symmetric waveform corresponds to 175 mV on either plateau, or about 1.75 mA in the same 100 Ω resistor. Record the measurement definition and the plateau used in the calculation. Measure or look up the oscillator supply current separately, as it includes the device's internal circuit consumption.

What changes if the receiver already has termination?

An internal 100 Ω resistance and an external 100 Ω resistance across the same pair give a 50 Ω equivalent. A first estimate can use an ideal current source. If the driver delivers 3.5 mA into 100 Ω and maintains the same total current when the load changes to 50 Ω, the differential plateau falls from about 350 mV to about 175 mV. Each 100 Ω branch carries approximately 1.75 mA. Driver output impedance, operating limits, the interconnect and resistor placement affect the actual waveform. Use the estimate to judge the order of magnitude, then compare a measurement at the receiver with its input requirements.

The input resistance also depends on the exact receiver part number. TI describes the SN65LVDS2 input as high impedance, while the SN65LVDT2 includes a 110 Ω resistor across its input. Adding an external 100 Ω resistor to the latter gives approximately 52.4 Ω in a DC parallel calculation. If the resistors sit at different physical points, the calculation still helps estimate the resistive load at steady state. Overshoot and ringing require checking placement, stub length and the interconnect. A resistance measurement with the board off is a clue. A programmable termination can change state when the receiver is powered and configured.

Use the waveforms to distinguish the failure modes

Trigger from the rail or OE, and capture oscillator power, enable and the waveform at the receiver on one timeline. Record receiver power, reset and lock if the diagnosis needs them. Start with a long time base to see the interval from power-up to stable clock activity. Then inspect the receiver waveform at nanosecond scale. A 125 MHz cycle takes 8 ns, so a capture of only a few cycles can miss a start-up delay measured in milliseconds.

At the receiverWhat to check next
The differential plateau changes around initialization.Confirm which resistor is fitted and when the receiver's termination setting takes effect. Compare manufacturer-supported configurations, changing only one termination condition at a time.
The differential amplitude looks suitable, but P and N drift in the same direction.Calculate their average through start-up. Compare that common-mode waveform with the input limits at the receiver's actual supply voltage.
A valid clock arrives after the receiver starts sampling or leaves reset.Check OE, oscillator power ramp and receiver reset timing against the applicable start-up definitions. Capture a cold start separately because the oscillator may already be running during a warm reset.
The plateau looks right, but the signal rings or crosses the threshold more than once.Check termination placement, stubs, probe connections and bandwidth. Inspect the threshold crossing as well as the static amplitude.

As a common-mode example, add 0.45 V to both original inputs. P becomes 1.825 V and N becomes 1.475 V. The differential voltage stays at 350 mV, while the common-mode level rises to 1.65 V. If a hypothetical receiver allows up to 1.50 V at that supply, the signal is outside its permitted input range. Use the actual receiver's electrical table for the decision. With DC coupling, compare guaranteed ranges across the relevant supply and temperature conditions. With AC coupling, verify the receiver bias network and the time it takes to settle.

Choose a differential probe with suitable bandwidth and input loading. If subtracting two matched channels, verify channel skew and reference connections, and use simultaneous samples for the common-mode calculation. Connecting both lines directly to grounded 50 Ω scope inputs changes the load and bias seen by the oscillator. A capture under that condition represents the modified circuit.

Keep the order code, load and start-up measurements together

The Epson SG3225VAN 125.000000 MHz KEGA provides a specific example. The ordering code is X1G0042410020xx, with the two packing digits defined in section 9. Section 2 lists a 2.25–3.63 V supply, 250–450 mV LVDS VOD, 1.15–1.35 V Vos and a 100 Ω load across the outputs. It also lists a 3 ms maximum start-up time. For a board reset schedule, check the specification's timing definitions against the actual power and enable sequence. These output figures apply to the stated configuration and load conditions. Use separate evidence for another 125 MHz oscillator or a 50 Ω load.

Keep the full order code, supply and temperature, receiver part number, termination states, measured plateaus and common-mode voltage, first stable clock and reset-release time in the same test record. That gives engineering and purchasing a shared baseline for comparing substitutes or changed ordering configurations.

Manufacturer references

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.