Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Spread-spectrum oscillators: how to specify frequency windows for center spread and down spread

If a receiver has a hard upper input-frequency limit, “100 MHz, 0.5% spread” on the purchase order still leaves the direction unspecified. For an ideal nominal reference, ±0.5% center spread sweeps from 99.5 to 100.5 MHz, while 0.5% down spread sweeps from 99.5 to 100 MHz.

If the nominal source for down spread is actually 20 ppm fast, the upper edge is already 100.002 MHz. A 0.5% sweep downward from that actual frequency reaches about 99.502 MHz. When assessing the full window, also calculate the low edge with the source at its slow limit. Use the worst case on each side.

SiTime's SiT9005 documentation lists center spread and down spread as separate options and specifies the modulation profiles. Check the actual order code for direction, definition of spread depth, modulation frequency, and enable conditions. Then confirm that the receiver supports that configuration. SiTime SiT9005 data sheet

Measuring instantaneous minimum and maximum requires resolving the modulation period. With a gate spanning many periods, a counter tends to report an average. Save the instrument window alongside the modulation period to avoid recording an average in a peak-limit field.

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.