Quartz crystal substitution: can lots with the same mean frequency error share an inspection result?

Suppose two quartz crystal lots both have a mean frequency error of 0 ppm. The slowest and fastest units in lot A are both within ±2 ppm. Lot B has units at −12 and +12 ppm. Those two values add to zero, illustrating how opposite errors can disappear in a mean. If the acceptance window per unit is ±10 ppm, lot B contains units outside it.

Which data to ask for after you see the mean

Record the signed frequency error, sample identifier and lot on each row. Include sample count, sampling method, temperature, load, fixture and reference timebase. Group by lot and look at the tails, possible clusters and whether the outliers share a fixture or assembly run. If the two sets were measured under different conditions, repeat under common conditions before comparing distributions.

Retest out-of-window samples with a verified measurement chain, and retain both the initial and repeat results. Qualification also requires checking the supplier's guaranteed limits and board performance at the operating limits. If you test only ten units, report the results for those ten. Use the approved sampling plan for production acceptance.