3225 differential oscillators: converting P/N trace-length mismatch to skew

The layout tool reports a 3 mm P/N mismatch, but the receiver specifies a time limit. Ask the board fabricator or signal integrity engineer which layer carries that 3 mm difference. For a same-layer segment with an assumed propagation delay of 6 ps/mm, the length mismatch corresponds to about 18 ps of skew. Propagation speed can differ by layer, so calculate multilayer paths segment by segment.

How a 30 ps budget gets used

If the project allocates 30 ps to the whole path and the trace segment uses 18 ps, 12 ps remains on paper. Account separately for the path from the oscillator to the pad, layer-change vias, connectors and the receiver package. Flag unmodeled sections for verification. Do not commit all of the remaining 12 ps to serpentine compensation. Skew has a direction in each segment, so combine the contributions according to the project's worst-case convention.

For board verification, first connect both measurement channels to the same edge and calibrate their relative delay. Then measure the rising P and falling N edges at the receiver using the same threshold definition, and record which line crosses first. If that direction contradicts the routing calculation, check omitted path segments and measurement connections before deciding where to revise the layout. TI high-speed interface routing guidelines, Section 2.3

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.