Suppose the available clearance from the PCB surface to the inside of the cover is 4.0 mm and the HC-49S has a maximum mounting height of 3.7 mm. On paper, that leaves 0.3 mm. Check the reference surfaces for both dimensions. If the 3.7 mm dimension is measured from the crystal base and a spacer raises the part, the calculation omits the spacer.
Calculate clearance using a cross section
Use the same PCB surface as the datum for the standoff, the maximum height of the part, and the inner surface of the cover. If 4.0 mm is a nominal clearance, subtract the inward cover tolerance, assembly offset, and board bow. If mechanical engineering supplies a minimum clearance that already includes these allowances, count each allowance only once.
A cover that closes establishes that this prototype fits. Show assembly where the clearance is smallest and have them check a real unit with a suitable gauge. Then assess the risk of contact under the project’s vibration conditions. Include the maximum mounting height and its reference surface in the request for quotation. A picture cannot supply either dimension.