A 48 MHz clock with guaranteed 45% to 55% duty cycle leaves little margin for a receiver requiring both high and low pulses to last at least 9 ns. The nominal period is 20.833 ns. The shortest high pulse is 45% of that period, and the shortest low pulse is 1 − 55%, also 45%. Both are approximately 9.375 ns, only 0.375 ns above the requirement.
Which two specifications can you subtract directly?
First check the supply voltage, output load, and measurement threshold used to guarantee duty cycle. Then check the receiver's threshold for its 9 ns requirement. If the definitions differ, measure again at the receiver pin using the receiver's specified thresholds. A 9.375 ns measurement at the waveform midpoint cannot be carried over directly.
Use the shortest period at the highest actual frequency in the budget. Capture multiple waveforms at the same threshold and record the narrowest high and low pulses separately. Check the jitter conditions and instrument uncertainty, and avoid subtracting terms already included in a guaranteed limit. If the remaining few hundred picoseconds are comparable to the measurement uncertainty, flag the margin for confirmation.