A 32 kHz crystal's specified CL is its required effective load. The pF value in an RTC manual can describe either the effective load of the whole oscillator circuit or the capacitance connected to one IC pin. Those definitions lead to different external capacitor values. Draw both crystal connections and label the installed components and internal capacitance at each pin before selecting the external capacitors.
If the manual specifies capacitance on each side, add internal and external capacitances in parallel at each pin first. Then combine the two sides as a series equivalent and include any parasitics not already accounted for. If the manual gives an effective CL setting directly, follow the instructions for external components at that setting. Halving it again underestimates the load.
If drift starts only after wake-up, read back the software settings first
Keep three records from the same board: immediately after power-up, after initialization by production firmware, and after wake-up from sleep. Record the actual register values and frequency offset at the same buffered output for each. Also save the values of both fitted capacitors. If the offset appears only after a firmware change, restore the previous setting and repeat the measurement. This check can show whether a firmware fix is sufficient before another board spin.
Some ICs include internal capacitance for a specified CL. Another RTC may directly specify the required external crystal load. Check the exact RTC part number. For example, the DS14285 crystal input calls for 6 pF. A usual value from a different RTC does not apply. ADI DS14285 product documentation