Export four rising edges from a single capture. Suppose their timestamps are 0, 10.01, 20.00, and 30.01 ns. Subtract successive timestamps to get the consecutive periods, then decide what to calculate next based on the acceptance criterion.
| Cycle number | Measured period | Subtract the nominal 10 ns | Subtract the preceding period |
|---|---|---|---|
| 1 | 10.01 ns | +10 ps | No preceding period |
| 2 | 9.99 ns | −10 ps | −20 ps |
| 3 | 10.01 ns | +10 ps | +20 ps |
In this example, the largest absolute period error is 10 ps and its peak-to-peak span is 20 ps. The largest absolute difference between adjacent periods is already 20 ps. The signed adjacent-period differences span 40 ps peak to peak. An inspection sheet that states only “20 ps jitter” can therefore refer to different calculations.
Specify whether the reference period is nominal or the sample mean, and whether the statistic is RMS, maximum absolute deviation, or peak to peak. Retain the number of cycles, whether slow drift was removed, and the raw timestamps so both parties can recalculate using the same edge sequence. SiTime: clock jitter definitions and measurement methods