A 100 MHz CMOS oscillator drives two ICs. If each input is 6 pF and the combined trace estimate is 5 pF, the lumped load at the source is about 17 pF. Compare that figure with the specified load for the actual output at its operating supply voltage. Check whether the estimate already includes pads and connectors.
Check each branch even if 17 pF is within the load limit
Mark the branch point, the two signal paths, and the actual probe positions beside the schematic. When edge time and trace propagation time are comparable, reflections can produce different waveforms at the near and far ends. Check each end for valid levels, repeated crossings of the receiver threshold, and the timing difference between corresponding effective edges.
If the load exceeds the guaranteed range or the two paths cannot meet synchronization requirements, evaluate a fanout buffer. Budget each receiver separately at its own buffer output, and check the buffer's added propagation delay, output-to-output skew, and additive jitter. Successful operation with one receiver only verifies the original light-load case. For acceptance with both active, keep both waveforms and record the simultaneous operating conditions.