Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Digital Interfaces and Clock Division

11.0592 MHz crystals: does 115200 baud divide evenly?

An 11.0592 MHz crystal can yield 115200 baud under two conditions: the UART actually receives this clock, and it uses 16× oversampling. In a simple integer-divider model, 11,059,200 ÷ (16 × 115,200) = 6 exactly. Some controllers store the divisor minus one in the register, so check the datasheet's encoding table before writing a value.

Verify the calculation with a transmitted byte

Transmit a repeating byte with alternating bits, such as 0x55, and measure the interval between adjacent data transitions on TX. At 115200 baud, one bit lasts about 8.68 µs. If the interval is close to 17.36 µs, read the UART clock selection, bus prescaler and oversampling setting. Crystal fine-tuning cannot readily account for an error of that size.

For a small bit-width error, check the timebase. If the board clock runs 30 ppm fast, the ideal integer-divided baud rate also runs about 30 ppm fast. Assess usable link tolerance using the remote clock error, frame format and UART sampling tolerance. Exact division at one end alone cannot establish the error limit for the whole link.

In the TI TL16C550C, the divider output feeds the internal 16× clock logic. If the debug software prints only a requested rate of 115200, read back the actual divisor latches and compare them with the manufacturer's baud rate table. TI TL16C550C baud rate table