Low-power RTC: why include leakage in the backup battery budget?

If the backup battery has 20 mAh of usable capacity, dividing by the RTC's 0.5 µA alone gives 40,000 hours. If the board adds 1.5 µA of leakage, the backup branch actually draws 2 µA. Under the same assumptions, life falls to 10,000 hours, or about 417 days.

Taking one year as 8,760 hours, 2 µA already requires 17.52 mAh, leaving only 2.48 mAh from 20 mAh. Whether that margin is usable depends on the battery capacity at the intended temperature and minimum operating voltage, as well as self-discharge. A one-year battery-life approval requires more than the device's typical current.

Where to put the ammeter in series

Disconnect main power and measure current between the battery and the entire backup branch. Check whether the meter's burden voltage changes the supply switchover state. If current exceeds the budget, disconnect loads such as resistor dividers, protection components, and unpowered I/O branches one at a time and observe the difference. Cover an entire cycle for intermittent circuits and check PCB surface leakage under hot and humid conditions. Epson RX8900SA: backup supply changeover