Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Precision TCXOs: how much timing error accumulates in 10 minutes without GPS?

After GPS lock is lost, the time error over the next 10 minutes depends on the average frequency offset during those 600 seconds and on the error already present when synchronization was lost. An offset of 1 ppm accumulates 1 µs per second. If the clock stays 0.5 ppm fast throughout, it gains 300 µs in 10 minutes.

Include the initial timing error in the 100 µs budget

The starting error changes the budget for the same 600-second holdover interval
Initial absolute time errorRemaining time budgetMaximum average frequency offset (approx.)
0 µs100 µs0.167 ppm
25 µs75 µs0.125 ppm

Allocate the error in the worst-case direction. Divide the remaining microseconds by the holdover time in seconds to get the allowable average frequency offset in ppm. When selecting a TCXO, account for the temperature profile after loss of lock, aging, and the holdover state of the original control loop. A typical room-temperature value does not represent those conditions.

During testing, cause the device to lose synchronization in the same way it would in service and measure time error against an independent reference. Record phase before and at loss of lock, temperature and time error throughout holdover, and the step on reacquisition separately. Cutting system power adds a restart and tests a different condition.