To answer what fraction 1 ps of jitter represents, first define the denominator. A 100 MHz clock has a 10 ns period, so 1 ps RMS is one ten-thousandth of a period, or 0.01%. At 200 MHz the period is 5 ns, and the same 1 ps represents 0.02%. The absolute time error remains the same.
In a serial interface, distinguish the reference clock period from the data unit interval (UI). At 1 Gb/s, one bit lasts 1 ns, one tenth of a 100 MHz reference-clock period. If the receiver specifies a data UI or a jitter transfer function for acceptance, follow its definition.
Before comparing two “1 ps RMS” quotes, record the carrier, lower and upper integration offsets, output configuration, and measurement conditions. If the bandwidths differ, request results over the same band or integrate the complete phase-noise spectra again. Report the absolute time and the denominator used. Peak-to-peak sample data cannot be converted to RMS with a universal multiplier. SiTime phase-noise integration tool