To find the frequency change per 1 mV on a VCXO, first choose the control voltage region where the loop operates. Suppose a 100 MHz device rises by 1 kHz as its control voltage goes from 1.4 V to 1.6 V. The shift is +10 ppm. Average gain over that interval is +50 ppm/V, or +5 Hz/mV.
Extract three quantities from the same curve
First check the direction of tuning. The way frequency responds as control voltage rises determines the feedback polarity. Next, measure local gain. Take two nearby points around each of the low end, lock point and high end. Hold temperature and supply constant, wait for the readings to stabilize, and divide the signed frequency change by the voltage change. Finally, mark the usable voltage range. If the curve flattens near an endpoint, the remaining voltage yields less frequency headroom than the slope at the midpoint suggests.
Give loop designers the original voltage and frequency readings and the datasheet's minimum and maximum gain. A static sweep cannot establish how fast the loop can track. Obtain modulation bandwidth from the part documentation or measure it separately at the specified frequencies. SiTime voltage-controlled oscillator documentation