RTC clock outputs: why check edge timing when the frequency is low?

A 32.768 kHz active clock has a period of about 30.5 µs. The receiver switches during the brief interval when the voltage crosses its threshold. A long period does not guarantee a sufficiently fast threshold crossing. Output drive setting, series resistance, wiring, input capacitance, and probe capacitance can all affect the edge at the receiver pin.

Use the same definition for both rise-time readings

If the device specification measures from 20% to 80% and the oscilloscope is set to 10% to 90%, the same monotonic edge usually yields two different readings. Keep the original capture and repeat the measurement in software using the specified lower and upper thresholds. If the waveform rings or has steps, state which crossings you use. A fixed conversion factor from another report may not apply.

Measure the steady-state waveform at the receiver pin and document the supply, actual load, and probe. If the problem appears only on wake-up, trigger on the enable signal and inspect the first valid edge and first pulse width separately. For a low-power RTC module, also check whether FOUT is enabled in the relevant supply mode. Epson RX8900SA: output and backup modes

Send us a part number or your requirements

Brand, frequency, quantity and delivery target — a useful place to start.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.